PRODUCTS SERIES
E-catalog/Mingguang Insulation
PDF
MICROPOROUS CALCIUM SILICATE BOARD
  Input��admin
  Microporous Calcium Silicate Materials (Non-asbestos)
Microporous calcium silicate products (650 degrees c) owns excellent characteristics: low thermal conductivity, high strengh, high service temperature, incombustible, good machinability, no corrosion and free from contamination. They are applied to electric power, heat pipes, chemical industry, metallurgy industry, boiler, kiln body, etc. In recent years, they are widely used in thermal power plant of heat-supply pipeline. Additionally, our company is capable of customizing non-standard products according to your requirements.
Physical performance data
GB/T 10699-1998
Physical Index
Unit
230
250
Bulk Density
kg/m3
230
250
Pressure Density
MPa
≥0.50
≥0.50
Flexural Density
MPa
≥0.30
≥0.30
Thermal Conductive
w/m.k
0.062
0.062
Temp. Limit
650
650
Linear Shrinkage
%
≤2
≤2
Block Sizes and Dimensional Tolerances
Name
Length   (mm)
Widthmm
Thicknessmm
Inside Diameter (ID)
Slab
100-600
100-300
30-100
——
Pipe
100-600
100-300
30-100
According to client request
 
Relation Sheet of Pipe Diameter, Thermal Medium Temperature and Thickness
Outside Diameter
Thermal Medium Temperature(Deg C)
(mm)
100
150
200
250
300
350
400
450
510
540
570
Φ57
30
40
50
55
60
60
65
65
70
70
70
Φ76
30
45
50
60
65
65
70
70
75
75
75
Φ89
30
45
55
60
65
65
70
75
75
75
75
Φ108
35
45
55
60
70
70
75
75
80
80
80
Φ133
35
50
60
65
70
75
80
80
80
85
85
Φ159
35
50
60
65
70
75
80
80
85
85
90
Φ219
35
50
65
70
75
80
85
90
90
90
90
Φ273
35
55
65
75
80
85
90
90
95
95
95
Φ325
35
55
65
75
85
85
90
95
95
95
100
Φ377
40
55
65
75
85
85
90
95
100
100
100
Φ426
40
55
70
80
85
85
95
95
100
100
100
Φ478
40
55
70
80
85
90
95
100
100
100
105
Φ529
40
55
70
80
85
90
100
100
105
105
105
Φ630
40
60
70
80
90
90
95
100
105
105
110
Φ720
40
60
70
85
90
95
100
 
 
 
 
Φ820
40
60
70
85
90
95
100
 
 
 
 
SLAB
40
65
80
90
100
105
110
 
 
 
 
Remark:
1. This is microporous calcium silicate products, according to the product thermal conductivity 0.048 Kcal/m.h. lambda = c and medium temperature preservation, to meet the international requirements (i.e., the surface temperature < 50 ° c) required thickness of products.
2.  And general temperature, and the thickness of the integer 10mm for grading unit.
3.  1Kcal, m.h. / w/c = 1.163 m.k.
4.  The table is just for reference in design and construction.
5.  The cross of tables and heat pipe diameter medium temperature is the thickness figure.
 
  Quantity (M3) per 100 meter with corresponding diameter and thickness
T
D
30
40
50
60
70
80
90
100
Φ76
0.998
1.46
1.98
2.56
3.21
3.92
4.69
5.53
Φ89
1.12
1.62
2.18
2.81
3.49
4.25
5.06
5.73
Φ108
1.30
1.86
2.48
3.02
3.91
4.72
5.60
6.53
Φ159
1.78
2.50
3.28
4.13
5.03
6.00
7.04
8.13
Φ219
2.35
3.25
4.22
5.26
6.35
7.51
8.73
10.02
Φ273
2.73
3.93
5.08
6.27
7.54
8.87
10.26
11.71
Φ325
3.34
4.58
5.89
7.25
8.68
10.17
11.72
13.35
Φ426
4.30
5.85
7.47
9.16
10.90
12.71
14.58
16.52
Φ478
4.79
6.51
8.29
10.14
12.05
14.02
16.05
18.15
Φ529
5.27
7.15
9.09
11.10
13.17
15.30
17.50
19.75
Φ630
6.22
8.42
10.68
13.00
15.39
17.84
20.35
22.92
Φ720
7.07
9.55
12.09
14.50
17.36
20.10
22.89
25.75
2010-5-4 21:39:55 [Close] [Top]